Dynavector | XX-2A
SPECIALLY ANNEALED MAGNETIC CIRCUIT
£1,799
Tel. 01736 368004
Established in 1978, Dynavector has been at the forefront of high-end audio manufacturing, introducing a multitude of high-performance cartridges to the market. Our approach to development is deeply rooted in academic engineering theory, a tradition passed down by our founder (*1).
Since the 1990s, we have pioneered the development of cutting-edge vibration systems, including ultra-fine wire high-output coils and gemstone cantilevers. Central to our focus has been the refinement of magnetic circuits. As a result, Flux Damper (*2) to stabilise magnetic flux and Softened Magnetism (*3) to reduce magnetic flux fluctuations were developed and installed into our cartridges.
In 2024, we achieved a significant breakthrough by enhancing the physical properties of our magnetic circuits, resulting in unparalleled sound quality.
Since the 1990s, we have pioneered the development of cutting-edge vibration systems, including ultra-fine wire high-output coils and gemstone cantilevers. Central to our focus has been the refinement of magnetic circuits. As a result, Flux Damper (*2) to stabilise magnetic flux and Softened Magnetism (*3) to reduce magnetic flux fluctuations were developed and installed into our cartridges.
In 2024, we achieved a significant breakthrough by enhancing the physical properties of our magnetic circuits, resulting in unparalleled sound quality.
(*1) Founder: Dr. Noboru Tominari (1927~2002), Doctor of Engineering Tokyo University, Former Professor at the Department of Mechanical Engineering Tokyo Metropolitan University
(*2) FLUX DAMPER: By wrapping a closing coil on the front yoke, the flux damper stabilizes flux disturbance caused by the vibration power from the cantilever and coil, giving a more natural sound. (Patented)
(*3) SOFTENED MAGNETISM: High-power magnets like neodymium have extremely high internal magnetic resistance, which causes large fluctuations in magnetic flux density and deteriorates sound quality. A highly permeable material is attached to the magnet to reduce the magnetic resistance of the magnetic circuit while maintaining magnetic force, preventing magnetic flux fluctuations and improving sound quality. (Patented)
(*2) FLUX DAMPER: By wrapping a closing coil on the front yoke, the flux damper stabilizes flux disturbance caused by the vibration power from the cantilever and coil, giving a more natural sound. (Patented)
(*3) SOFTENED MAGNETISM: High-power magnets like neodymium have extremely high internal magnetic resistance, which causes large fluctuations in magnetic flux density and deteriorates sound quality. A highly permeable material is attached to the magnet to reduce the magnetic resistance of the magnetic circuit while maintaining magnetic force, preventing magnetic flux fluctuations and improving sound quality. (Patented)
INTRODUCING THE SPECIAL ANNEALING MAGNETIC CIRCUIT
While an exceptional vibration system is essential for a high-performance MC cartridge, we emphasise the critical role of the magnetic circuit. The cartridge's output signal is intricately tied to the movement of the vibration system within the magnetic circuit, where electricity is generated as the coil vibrates amidst the magnetic flux.
To ensure optimal output, it is imperative that the magnetic flux maintains high density and stability. We employ pure iron for our magnetic circuit due to its high magnetic permeability and exceptional stability, resulting in a distortion-free output. However, the processing of metal parts often distorts the crystal structure at the atomic level, leading to a loss of magnetic permeability.
Magnetic annealing, a process of heating and cooling processed parts, is crucial for restoring the distorted metal crystal structure and regenerating magnetic permeability. However, a generic magnetic annealing cannot fully restore distortions in the crystal structure. The magnetic annealing conditions vary depending on the parts material, size, shape, etc. Our recent development focused on finding the best magnetic annealing process, including temperature, environment, duration, and heating and cooling rates. This meticulous approach has enabled us to unleash the full potential of pure iron's unique magnetic performance.
The new magnetic circuit has significantly enhanced sound quality, delivering unrivalled resolution, smooth wide-range expression, and expansive sound field. Experience the natural and dynamic sound of the Dynavector XX-2A cartridge, where an exceptional vibration system harmonises seamlessly with an optimised magnetic circuit.
To ensure optimal output, it is imperative that the magnetic flux maintains high density and stability. We employ pure iron for our magnetic circuit due to its high magnetic permeability and exceptional stability, resulting in a distortion-free output. However, the processing of metal parts often distorts the crystal structure at the atomic level, leading to a loss of magnetic permeability.
Magnetic annealing, a process of heating and cooling processed parts, is crucial for restoring the distorted metal crystal structure and regenerating magnetic permeability. However, a generic magnetic annealing cannot fully restore distortions in the crystal structure. The magnetic annealing conditions vary depending on the parts material, size, shape, etc. Our recent development focused on finding the best magnetic annealing process, including temperature, environment, duration, and heating and cooling rates. This meticulous approach has enabled us to unleash the full potential of pure iron's unique magnetic performance.
The new magnetic circuit has significantly enhanced sound quality, delivering unrivalled resolution, smooth wide-range expression, and expansive sound field. Experience the natural and dynamic sound of the Dynavector XX-2A cartridge, where an exceptional vibration system harmonises seamlessly with an optimised magnetic circuit.
BENIFITS OF MAGNETIC ANNEALING
Magnetic annealing rejuvenates the distorted crystal structure, restoring magnetic permeability to its original state.
FEATURES
ALNICO MAGNET AND FLUX DAMPING
Incorporating Alnico magnets with low magnetic resistance into the magnetic circuit, the XX-2A ensures minimal fluctuation in magnetic force during record playback. Compared to mainstream high-energy rare-earth magnets, such as samarium cobalt and neodymium boron, Alnico magnets contribute to a high signal-to-noise ratio (S/N) and excellent transient response. Additionally, patented Flux Damping technology stabilises magnetic flux within the air gap, ensuring consistent performance akin to higher-tier models.... learn more about Flux Damping and Softened Magnetism HIGH RIGIDITY MAGNETIC CIRCUIT Crafted with stainless bolts securing the front and rear yokes along with the magnets, the XX-2A boasts a high-rigidity magnetic circuit. Skilled artisans meticulously adjust tightening torque during assembly, a process crucial for maintaining sound quality and ensuring optimal performance for each unit. |
LOW-OUTPUT MC CARTRIDGE
With an output voltage of 0.28mV, the XX-2A conforms to the general level for MC cartridges, making it compatible with various amplifiers and transformers including the SUP-200. With a recommended load impedance of more than 30 ohms that ensures suitability for different load settings, including 47k ohms (phono stage input). COMPLIANCE Featuring a compliance of 10mm/N and weighing 8.9g, the XX-2A cartridge is compatible with a wide range of tonearms, from light to medium mass. We recommend the use of a light weight headshell to optimise performance. SOLID BORON CANTILEVER The XX-2A is equipped with a 6mm length solid boron cantilever, coupled with a PathFinder (PF) line contact stylus, creating a lightweight and rigid vibration system for enhanced playback accuracy. |
SPECIFICATIONS
Type
low output moving coil cartridge with flux damper and alnico magnet Output Voltage 0.28 mV (at 1KHz, 5cm/sec.) Channel Separation 30 dB (at 1KHz) Channel balance 1.0 dB (at 1KHz) Frequency response 20 - 20,000 Hz(±1dB) Compliance 10 mm/N |
Tracking force
1.8 - 2.2 g Impedance 6 ohms Recommended load impedance > 30 ohms Cantilever 6mm length solid boron Stylus tip PF Line contact shape, stylus radius: 7 x 30 micron Weight 8.9 g |